1001
|
Advanced breast biopsy instrumentation
|
Safe
|
Available evidence does not suggest
|
Not undertaken
|
Diagnostic – biopsy
|
1004
|
Transmyocardial laser revascularization
|
Carries risk & adverse events
|
Studies do not demonstrated/sustained effect not proven
|
Savings if effects sustained
|
Therapeutic
|
1008
|
Photodynamic therapy for skin and mucosal cancer
|
Safe
|
Trials too small, unproven
|
Not available
|
Therapeutic
|
1009
|
Sacral nerve stimulation for urinary incontinence
|
Relatively high adverse event rate
|
Uncertain long term
|
Expensive
|
Surgical
|
1011
|
Lung volume reduction surgery – for advanced emphysema
|
Differs widely
|
Limited data – not possible to determine long term
|
Insufficient information
|
Surgical
|
1012
|
Vertebral axial decompression therapy for chronic back pain
|
Detailed evidence lacking
|
Some/insufficient
|
No evidence based conclusion can be drawn
|
Therapeutic
|
1023
|
Placement of artificial bowel sphincters in the management of faecal incontinence
|
Could not be assessed due to insufficient data
|
Lack of rigorous studies – not demonstrated
|
Could not be assessed
|
Surgical
|
1028
|
Gamma knife surgery
|
Lack of data – unproven
|
Uncertain
|
Lack of safety & effectiveness data
|
Surgical
|
1030
|
Low intensity ultrasound treatment for the acceleration of bone fracture healing – Exogen\texttrademark bone growth stimulator
|
Safe for adults
|
Trial results contradictory
|
Unfavourable
|
Therapeutic
|
1032
|
Intravascular ultrasound
|
Relative safe overall
|
Insufficient evidence
|
Insufficient evidence
|
Diagnostic
|
1034
|
Selective Internal Radiation Therapy for hepatic Metastases using SIR-Spheres®
|
Limited evidence
|
Some but insufficient evidence
|
Not possible due to unreliable evidence
|
Therapeutic
|
1044
|
Ostase immunoassay for the mass measurement of serum bone alkaline phosphatase
|
No safety risk
|
Insufficient evidence
|
Not performed
|
Diagnostic
|
1045
|
Intra-articular viscosupplementation for treatment of osteoarthritis of the knee
|
May be at least as safe as alternatives
|
Limited evidence – as effective as alternatives
|
Little valid information but more expensive
|
Therapeutic
|
1046
|
Interstim for sacral nerve stimulation in patients with refractory urinary incontinence
|
Adverse event incidence relatively high
|
Effective but unproven for longer than 12 months
|
Not published
|
Surgical
|
1047
|
Endoluminal Gastroplication for the Treatment of Gastro- Oesophageal Reflux Disease (GORD)
|
Limited evidence – more data required
|
May be effective – Limited good quality data
|
Insufficient data
|
Surgical
|
1048
|
Intradiscal electrothermal anuloplasty for patients with chronic low back pain due to anular disruption of contained herniated discs
|
Low complications
|
Based on low level evidence
|
Insufficient evidence
|
Surgical
|
1049
|
M-VAX TM – a treatment for patients with advanced stage III melanoma
|
Unable to determine due to poorly reported data
|
Not possible to assess due to low level evidence
|
Insufficient data
|
Therapeutic
|
1053
|
Placement of artificial bowel sphincters in the management of faecal incontinence
|
Number of safety issues
|
Misleading findings
|
Not possible due to lack of clinical evidence
|
Surgical
|
1054
|
Hyperbaric Oxygen Therapy (Resubmission)
|
High rate adverse events
|
Studies flawed – uncertain benefits
|
Not possible
|
Therapeutic
|
1055
|
Hysteroscopic sterilisation by tubal cannulation and placement of intrafallopian implants
|
Appears to be relatively safe – short term data
|
Appears to be relatively effective – short term data
|
No evidence
|
Surgical
|
1059
|
Endo Venous Laser Treatment for Varicose Veins
|
Safe
|
Insufficient evidence
|
Insufficient evidence
|
Therapeutic
|
1062
|
A scan for Imaging Recurrence and/or metastases in patients with histologically demonstrated carcinoma of the colon or rectum
|
Safe
|
Insufficient evidence
|
Insufficient evidence
|
Diagnostic
|
1067
|
Genotypic resistance testing of antiretrovirals in HIV
|
Appears to be safe
|
Insufficient evidence
|
Insufficient evidence
|
Diagnostic
|
1071
|
Measurement of international normalised ratio (INR) in general practice
|
No excessive safety concerns
|
Limited data
|
Limited to direct costs – uncertainty of effectiveness
|
Diagnostic
|
1078
|
Multifocal multichannel objective perimetry (MMOP)
|
Safe
|
Insufficient evidence
|
Could not be determined
|
Diagnostic
|
1083
|
Intac Implants
| |
Evidence pertaining to this procedure is immature and small in volume.
|
Lack of published comparative clinical studies does not allow for any cost effectiveness analysis
|
Surgical
|